Torna all'elenco della categoria: Irel Iskra Relays
Versione stampabile del prodotto: TRK 10 ::Miniature Power :Relay

TRK 10
Miniature Power
Relay

Pag: 1 - 2 - 3
ATECO
Irel Iskra Relays
TRK 10 ::Miniature Power :Relay
  • 200 mW rated power
  • 6A, 250VAC contact load
  • Ambient temperature up to +85°C
  • 4 kV test voltage between coil and contact
  • According to EN 60950 (IEC 950, VDE 0805)
  • Washable version, extinguishable casing, plastic bars packing
  • UL approval, VDE in process to acquiring

Technical data

Characteristics

  • Contact Form: 1 Change - Over, 1 Make, 1Break
  • Rated Current: 6A and 5A
  • Contact Material: 6A AgCdO AgSnO2
    5A AgNi10
    By request with Au clad
  • Max. Operating Voltage: 380VAC, 220VDC
  • Max. Switching Power: 6A 1500VA 144W - 5A 1250VA 120W
  • Min. Switching Load: 5VDC 100mA
  • Contact Resistance: ≤ 100 mΩ - 100mA 5VDC (New relay)
  • Max. Operating Frequency:
    360 operations/h rated load
    36000 operations/h min. load
  • Capacitance cont-cont: ≤1,5 pF
  • Mechanical Life: ≥ 2x107 operations
  • Electrical Life: See diagram
  • Rated Power: abt. 200 mW
  • Max. Coil Temperature: 155°C
  • Thermal Resistance: abt. 155 K / W
  • Operate Voltage (cold coil): Uop ≤ 78% Un
  • Release Voltage: Ure ≥ 10% Un
  • Operative Range: class 1, IEC61810-1
  • Test Voltage (1 min.): contact-coil ≥ 4 kV rms 50 Hz
    contact-contact ≥ 1 kV rms 50 Hz
  • Degree of Pollution: 2, IEC 60664-1
  • Overvoltage Category: III, IEC 60664-1
  • Creepage Distances: contact-coil: ≥ 5.5 mm
  • Clearences: contact-coil: ≥ 4.5 mm
  • Impulse Voltage Test (1,2/50 µs): contact-coil ≥ 5 kVimp
  • Operate Time at Un: abt. 6 ms
  • Release Time: abt. 4 ms
  • Bouncing Time: abt. 2 ms make abt. 10 ms break
  • Insulation Resistance (500 VDC): > 1000 MΩ
  • Vibration Resistance (10-200Hz): 10 gn IEC 60068-2-6
  • Shock Resistance (11 ms): IEC 60068-2-27 functional 20 gn
    IEC 60068-2-27 destructive 100 gn
  • Ambient Temperature: operating -40°C/+70°C,
    storage -40°C/+85°C
  • Protection Degree: IP 67, IEC 529
  • Seal Test (1min): Qc/2, IEC 60068-2-17
  • Case Extinguishing: V-0, UL 94
  • Mounting Position: optional, 5 mm between relays
  • Relay Weight: abt. 5 g

Coil data at 20°C

Coil Rated Voltage Coil Resistance Operative Coil Voltage Range
Must Operate Must Release UMAX
Un (VDC) Rn(Ω) ± 10% Uop ≤ (VDC) Ure ≥ (VDC) (VDC)
3 45 2.3 0.3 6
5 125 3.9 0.5 11
6 180 4.7 0.6 13
9 405 7.0 0.9 19
12 720 9.4 1.2 26
18 1620 14.0 1.8 39
24 2880 18.7 2.4 52
36 6480 28.1 3.6 78
48 11520 37.4 4.8 104
Pag: 1 - 2 - 3