TRK 10
Miniature Power
Relay

Irel Iskra Relays

- 200 mW rated power
- 6A, 250VAC contact load
- Ambient temperature up to +85°C
- 4 kV test voltage between coil and contact
- According to EN 60950 (IEC 950, VDE 0805)
- Washable version, extinguishable casing, plastic bars packing
- UL approval, VDE in process to acquiring
Technical data
Characteristics
- Contact Form: 1 Change - Over, 1 Make, 1Break
- Rated Current: 6A and 5A
- Contact Material: 6A AgCdO AgSnO2
5A AgNi10
By request with Au clad - Max. Operating Voltage: 380VAC, 220VDC
- Max. Switching Power: 6A 1500VA 144W - 5A 1250VA 120W
- Min. Switching Load: 5VDC 100mA
- Contact Resistance: ≤ 100 mΩ - 100mA 5VDC (New relay)
- Max. Operating Frequency:
360 operations/h rated load
36000 operations/h min. load - Capacitance cont-cont: ≤1,5 pF
- Mechanical Life: ≥ 2x107 operations
- Electrical Life: See diagram
- Rated Power: abt. 200 mW
- Max. Coil Temperature: 155°C
- Thermal Resistance: abt. 155 K / W
- Operate Voltage (cold coil): Uop ≤ 78% Un
- Release Voltage: Ure ≥ 10% Un
- Operative Range: class 1, IEC61810-1
- Test Voltage (1 min.): contact-coil ≥ 4 kV rms 50 Hz
contact-contact ≥ 1 kV rms 50 Hz - Degree of Pollution: 2, IEC 60664-1
- Overvoltage Category: III, IEC 60664-1
- Creepage Distances: contact-coil: ≥ 5.5 mm
- Clearences: contact-coil: ≥ 4.5 mm
- Impulse Voltage Test (1,2/50 µs): contact-coil ≥ 5 kVimp
- Operate Time at Un: abt. 6 ms
- Release Time: abt. 4 ms
- Bouncing Time: abt. 2 ms make abt. 10 ms break
- Insulation Resistance (500 VDC): > 1000 MΩ
- Vibration Resistance (10-200Hz): 10 gn IEC 60068-2-6
- Shock Resistance (11 ms): IEC 60068-2-27 functional 20 gn
IEC 60068-2-27 destructive 100 gn - Ambient Temperature: operating -40°C/+70°C,
storage -40°C/+85°C - Protection Degree: IP 67, IEC 529
- Seal Test (1min): Qc/2, IEC 60068-2-17
- Case Extinguishing: V-0, UL 94
- Mounting Position: optional, 5 mm between relays
- Relay Weight: abt. 5 g
Coil data at 20°C
Coil Rated Voltage | Coil Resistance | Operative Coil Voltage Range | ||
---|---|---|---|---|
Must Operate | Must Release | UMAX | ||
Un (VDC) | Rn(Ω) ± 10% | Uop ≤ (VDC) | Ure ≥ (VDC) | (VDC) |
3 | 45 | 2.3 | 0.3 | 6 |
5 | 125 | 3.9 | 0.5 | 11 |
6 | 180 | 4.7 | 0.6 | 13 |
9 | 405 | 7.0 | 0.9 | 19 |
12 | 720 | 9.4 | 1.2 | 26 |
18 | 1620 | 14.0 | 1.8 | 39 |
24 | 2880 | 18.7 | 2.4 | 52 |
36 | 6480 | 28.1 | 3.6 | 78 |
48 | 11520 | 37.4 | 4.8 | 104 |