TRK 17
Miniature Power
Relay

Irel Iskra Relays

- Rated coil power 0.28 W, 0.33 W, 0.45 W
- Max. contact current 7A or 10A
- Ambient temperature up to +70°C
- Washable version Qc/2
- Extinguishable casing V-0
- Plastic bars packing
- UL, VDE, S approval
Technical data
Characteristics
- Contact Form: 1 Change - Over, 1 Make, 1Break
- Rated Current: 7A and 10A
- Contact Material: 7A AgNi10
10A AgCdO (AgSnO by special request) - Max. Operating Voltage: 230VAC, 220VDC (see diagram)
- Max. Switching Power: 7A 1750VA 170W - 10A 2500VA 240W
- Min. Switching Load: 100mA 5VDC
- Contact Resistance: ≤ 100 mΩ - 5VDC 100 mA (New relay)
- Max. Operating Frequency:
7A 600 operations/h rated load 36000 operations/h min. load
10A 360 operations/h rated load 36000 operations/h min. load - Capacitance cont-cont: ≤ 1,5 pF
- Mechanical Life: ≥ 2x107 operations
- Electrical Life: See diagram
- Rated Power: high sensitive-H abt. 0.28 W
sensitive-F abt. 0.33 W
sensitive-F abt. 0.57 W for 60 V
standard abt. 0.45 W
standard abt. 0.61 W for 60 V - Max. Coil Temperature: 155°C
- Operate Voltage (cold coil): high sensitive-H Uop 78% Un
sensitive-F Uop ≤ 73% Un
standard Uop ≤ 70% Un - Release Voltage: Ure ≥ 10% Un
- Thermal Coil Resistance: abt. 110 K / W
- Operative Range: class 1, IEC61810-1
- Test Voltage (1 min.): contact-coil ≥ 4 or 2 kVrms 50 Hz
contact-contact ≥ 1 kVrms 50 Hz - Rated Impulse Voltage (1,2/50 µs): contact-coil ≥ 5 kVIMV
- Overvoltage Category: III, IEC 60664-1
- Degree of Pollution: 2, IEC 60664-1
- Operate Time at Un: abt. 7 ms
- Release Time: abt. 3 ms
- Bouncing Time: abt. 2 ms make abt. 10 ms break
- Insulation Resistance (500 VDC): > 103 MΩ
- Vibration Resistance (10-200Hz): 10 gn
- Shock Resistance (11 ms): functional 10 gn destructive 100 gn
- Ambient Temperature: operating -40°C/+70°C,
storage -40°C/+85°C - Protection Degree: IP 67, IEC 529
- Seal Test (1min): Qc/2, IEC 60068-2-17
- Case Extinguishing: V-0, UL 94
- Mounting Position: optional
- Relay Weight: abt. 8 g