  • Surge-proof electrolytic capacitor in aluminium can with insulation sleeve.
  • Safety vent at bottom case or aside case.
  • Snap in terminals for PCB mounting.

Very high CV for unit volume with low ESR.

High ripple current, in small dimensions case size.

Extended temperature range with outstanding reliability.

Applications

Professional switch mode power supplies.

Professional power electronics.

RoHS Compliant.


SPECIFICATION
  General Characteristics
Temperature Range Operating: -40°C +105°C           [Envirtonmental classification 40/105/56 IEC-68]
Storage: Preferably below +25°C, not exceeding +40°C
Rated Voltage Range (Vr) From 16V to 450V DC
Surge Voltage (Vp) Vp = 1.15 Vr (Vr ≤ 250V DC)
Vp = 1.10 Vr (Vr > 250V DC)
Rated Capacitance Range From 68 µF to 47,000 µF
Capacitance Tolerance ± 20% at 100 Hz, 20°C [M class IEC-62]
Leakage Current (IL) (mA, 5 min, 20°C) Max IL = 0.006 Cr Vr +4 µA           Kendeil product limit: IL = 0.003 CrVr
At 85°C max IL = 0.02 CrVr µA
Ripple Current (Ir) Refer to table at 105°C and 100 Hz. For different temperature and frequency multiplier must be used as follows:
Frequency 50 Hz 100 Hz 500 Hz 1.000 Hz >10k Hz  
Multiplier (0-25V Vr DC) 0.91 1.0 1.15 1.15 1.2  
Multiplier (40-100V Vr DC) 0.88 1.0 1.35 1.40 1.45  
Multiplier (160-450V Vr DC) 0.88 1.0 1.45 1.50 1.55  
 
Ambient Temperature 35°C 45°C 55°C 65°C 75°C 85°C 95°C 105°C
Multiplier 3.0 2.80 2.60 2.40 2.20 1.80 1.50 1.0
 
Maximum internal temperature 108°C  
Insulation Resistance At 100V DC for 1 min is >100 MΔ across insulating sleeve and terminals.
Vibration Resistance Frequency range: 10 Hz to 500 Hz, amplitude 0.75 mm
max acceleration 10g for 3x2 h
Life Test After 2,000 hours application of rated voltage at 105°C capacitors meet characteristics aside Cap change ≤ 20%
tan δ ≤ 200%
Leakage current (IL) < initial limit
Impedance (Z) ≤ 200%
Shelf life After leaving capacitors under no load for 500 hours at 85°C, when restored at 20°C meet specifications aside Cap change ≤ ±15%
tan d ≤ 150%
Leakage current (IL) < initial limit
Useful life > 250,000 h at 40°C
> 15,000 h at 85°C
≤ 5,000 h at 105°C
Failure percentage
Failure rate
≤ 1% (during useful life)
< 40 fit (40 10-9/h (Vr ≤ 160V DC)>
Self inductance Approx. 20 nH
Reference standards CECC 30.301 IEC 60384-4 LONG LIFE GRADE
Pag: 1 - 2 - 3 - 4 - 5